Power On Configuration The PSB-1000 series provides different Power On Configurations for different users. Users can also set automatic execution procedures to be carried out as soon as power is turned on. After presetting Power On Configuration, each rebooting will have a short activation display to show present settings of Power On Configuration of the PSB-1000 series. The execution will be conducted by the power on mode. Power On Configuration Parameters Include: 1. CV control settings: Local(master), Ext-V(external voltage control), Ext-R↗, Ext-R↘(external resistance control) 2. CC control settings: Local(master), Ext-V(external voltage control), Ext-R↗, Ext-R↘(external resistance control) 3. PON automatic execution while power on: None (non execution), Output On (automatic output while power is on), SEQ0~SEQ9 (automatic sequence execution while power is on) 4. Track series and parallel settings: Local (master operation), S/Slave (set as Slave under the series connection mode), P/Slave (set as Slave under the parallel connection mode), P2-P4/M (set as Master under the parallel connection mode) 5. Ext-Out external analog output control: set High to indicate pin18-19 open circuit (Open) power output. set Low to indicate pin18-19 short circuit (Short) power output. 6. Breaker: set Enable (while alarm is sounded, PSB-1000 will shut down automatically) set Disable (while alarm is sounded, PSB-1000 will cease outputting) 7. Sense Control set Disable (non activation of internal Remote sense terminal) set Rear (activation of rear panel internal Remote sense terminal) set Front (activation of front panel internal Remote sense terminal) 
POC setting screen |