The PFR-100 series, a small and high-performance programmable D.C. power supply, adopts natural convection design to dissipate heat. The fanless structure allows users to focus on their experiments and tests in a quiet environment. Fanless power supply will not suck in dust and foreign objects, therefore, PFR-100 series has a longer life cycle compared with that of power supplies with fan. The PFR-100 series is a power supply with a five-fold rated power that allows users to self-define voltage and current under rated power conditions so as to satisfy them with wider voltage and current operational ranges. PFR-100 series, with rated 100W, provides two models: PFR-100L- maximum output voltage of 50V (at 2A) or maximum output current of 10A (at 10V); PFR-100M maximum output voltage of 250V (at 0.4A) or maximum output current of 2A (at 50V). The PFR-100 series provides front and rear panel output terminals. The front panel output terminal helps users shorten test lead replacement time while conducting adjustment on front panel's function keys. The rear panel output terminal facilitates an easy wiring operation for rackmount assembly. 3U height, 70mm width and 2.5KG in weight have greatly elevated PFR-100 series portability. Furthermore, the multi-drop mode allows users to control up to 31PFR-100 series without using switch/Hub that help users save the equipment cost.
Specifications |
|
| PFR-100L | PFR-100M | OUTPUTRATING | Rated Output Voltage | 50V | 250V | Rated OutputCurrent | 10A | 2A | Rated OutputPower | 100W | 100W | REGULATION(CV) | Load Regulation (*2) | 10mV | 33mV | LineRegulation (*1) | 3mV | 5mV | REGULATION(CC) | Load Regulation (*9) | 10mA | 3.2mA | LineRegulation (*1) | 8mA | 1.2mA | RIPPLE &NOISE (*3) | Vp-p (*4) | 50mV | 150mV | Vr.m.s.(*5) | 4mV | 15mV | A r.m.s. | 10mA | 2mA | PROGRAMMINGACCURACY | Voltage | 0.1% of setting + | 40mV | 200mV | Current | 0.2%of setting + | 20mA | 2mA | MEASUREMENTACCURACY | Voltage | 0.1% of reading + | 40mV | 200mV | Current | 0.2% of reading + | 20mA | 2mA | RESPONSETIME | Rise Time (*6) | Rated load | 50ms | 200ms | Fall Time (*7) | Ratedload | 100ms | 300ms |
| Noload | 500ms | 3000ms | TransientResponse Time (*8) | 1.5ms | 2ms | PROGRAMMINGRESOLUTION | Voltage | 2mV | 10mV | Current | 1mA | 0.1mA | MEASUREMENTRESOLUTION | Voltage | 2mV | 10mV | Current | 1mA | 0.1mA | PROTECTIONFUNCTION | Over Voltage Protection (OVP) | Setting range | 5~55V | 5~275V | Over Current Protection (OCP) | Settingrange | 1~11A | 0.2~2.2A | Under Voltage Limit (UVL) | Settingrange | 0~52.5V | 0~262.5V | Over Temperature Protection (OTP) | Operation | Turnthe output off. | Turnthe output off. | Low AC Input Protection (AC-Fail) | Operation | Turnthe output off. | Turnthe output off. | Power Limit (Power Limit) | Operation | Turnthe output off. | Turnthe output off. | FRONT PANEL DISPLAY | Voltage | 0.1% of reading + | 40mV | 200mV | ACCURACY, 4 DIGITS | Current | 0.2%of reading + | 20mA | 2mA | ENVIRONMENTCONDITION | Operaing Temperature | 0°C to 40°C | StorageTemperature | -20°C to 70°C | OperatingHumidity | 20% to 80% RH; No condensation | StorageHumidity | 20% to 85% RH; No condensation | READBACK TEMP. COEFFICIENT | Voltage | 100ppm/℃ | (After A 30 Minute Warm-up) | Current | 200ppm/℃ | OTHER | Analog Control | Yes | Interface | USB, RS-232/RS-485; Factory option: LAN/GPIB | AC Input | 85~265VAC, 47~63Hz, single pahse | DIMENSIONS & WEIGHT | 70(W)x124(H)x300(D)mm; Approx.2.5kg | | | | | | Notes: | *1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load. | *2: From No-load to Full-load, constant input voltage. Measuredat the sensing point in Remote Sense. | *3: Measure with JEITA RC-9131B (1:1) probe | *4: Measurement frequency bandwidth is 10Hz to 20MHz. | *5: Measurement frequency bandwidth is 5Hz to 1MHz. | *6: From 10%~90% of rated output voltage, with rated resistiveload. | *7: From 90%~10% of rated output voltage, with rated resistiveload. | *8: Time for output voltage to recover within 0.1% + 10mV of itsrated output for a | load change from 50 to 100% of its rated output current. | *9: For load voltage change, equal to the unit voltage rating,constant input voltage.
|
|